Technical Specifications:
|
| Item | Specifications |
| Specifications | | |
| Maximum voltage between any terminal and earth ground | 600 V | |
| Surge protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 | |
| Display | 6,000 counts, updates 4 per second | |
| Bar graph | 33 segments, updates 32 per second | |
| Operating Temperature | -10 °C to + 50 °C | |
| Storage Temperature | -40 °C to + 60 °C | |
| Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
| Battery Life | 400 hours typical, without backlight | |
| | |
| Accuracy Specifications | | |
| DC millivolts | Range | 600.0 mV |
| Resolution | 0.1 mV |
| Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 |
| DC volts | Range/Resolution | 6.000 V / 0.001 V |
| Range/Resolution | 60.00 V / 0.01 V |
| Range/Resolution | 600.00 V / 0.1 V |
| Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 |
| Auto volts | Range | 600.0 V |
| Resolution | 0.1 V |
| Accuracy | 2.0 % + 3 (dc, 45 Hz to 500 Hz) |
| | 4.0 % + 3 (500 Hz to 1 kHz) |
| AC millivolts1 true-rms | Range | 600.0 mV |
| Resolution | 0.1 mV |
| Accuracy | 1.0 % + 3 (dc, 45 Hz to 500 Hz) |
| | 2.0 % + 3 (500 Hz to 1 kHz) |
| AC volts1 true-rms | Range/Resolution | 6.000 V / 0.001 V |
| Range/Resolution | 60.00 V / 0.01 V |
| Range/Resolution | 600.0 V / 0.1 V |
| Accuracy | 1.0 % + 3 (dc, 45 Hz to 500 Hz) |
| | 2.0 % + 3 (500 Hz to 1 kHz) |
| Continuity | Range | 600 ? |
| Resolution | 1 ? |
| Accuracy | Beeper on < 20 ?, off > 250 ?; detects opens or shorts of 500 ?s or longer. |
| Ohms | Range/Resolution | 600.0 ? / 0.1 ? |
| Range/Resolution | 6.000 k? / 0.001 k? |
| Range/Resolution | 60.00 k? / 0.01 k? |
| Range/Resolution | 600.0 k? / 0.1 k? |
| Range/Resolution | 6.000 M? / 0.001 M? |
| Accuracy | 0.9 % + 1 |
| Range/Resolution | 40.00 M? / 0.01 M? |
| Accuracy | 1.5 % + 2 |
| Diode Test | Range/Resolution | 2.000 V / 0.001 V |
| Accuracy | 0.9% + 2 |
| Capacitance | Range/Resolution | 1000 nF / 1 nF |
| Range/Resolution | 10.00 ?F / 0.01 ?F |
| Range/Resolution | 100.0 ?F / 0.1 ?F |
| Range/Resolution | 9999 ?F / 1 ?F |
| Range/Resolution | 100 ?F to 1000 ?F |
| Accuracy | 1.9% + 2 |
| Range/Resolution | > 1000 ?F |
| Accuracy | 5% + 20% |
| LoZ capacitance | Range | 1 nF to 500 ?F |
| Accuracy | 10% + 2 typical |
| Temperature2 (Type-K thermocouple) | Range/Resolution | -40 °C to 400 °C / 0.1 °C |
| Accuracy | 1% + 102 |
| Range/Resolution | -40 °F to 752 °F / 0.2 °F |
| Accuracy | 1% + 182 |
| AC ?amps true-rms (45 Hz to 500 Hz) | Range/Resolution | 600.0 ?A / 0.1 ?A |
| Accuracy | 1.0% + 2 |
| DC ?amps | Range/Resolution | 600.0 ?A / 0.1 ?A |
| Accuracy | 1.0% + 2 |
| Hz (V or A input)2 | Range/Resolution | 99.99 Hz / 0.01 Hz |
| Range/Resolution | 999.99 Hz / 0.1 Hz |
| Range/Resolution | 9.999 Hz / 0.001 Hz |
| Range/Resolution | 50.00 Hz / 0.01 Hz |
| Accuracy | 0.1% + 2 |
| | |
| Notes: | | |
| 1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. | | |
| 2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. | | |
| 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. | | |
| 4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F | | |
| | |
| | |
| Mechanical & General Specifications | | |
| Size | 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") | |
| Weight | 550 g | |
| Warranty | 3 years | |
| | |
| Fluke® 323 True-rms Clamp Meter | | |
| | |
| | |
| Specifications | | |
| AC current | Range 400.0 A | |
| Accuracy | 2 % ± 5 digits |
| | (45 Hz to 65 Hz) |
| | 2.5 % ± 5 digits |
| | (65 Hz to 400 Hz) |
| AC voltage | Range | 600.0 V |
| Accuracy | 1.5 % ± 5 digits |
| DC voltage | Range | 600.0 V |
| Accuracy | 1.0 % ± 5 digits |
| Resistance | Range | 400.0 ?/ 4000 ? |
| Accuracy | 1.0 % ± 5 digits |
| Continuity | | ? 70 ? |
| AC response | | True-rms |
| Data hold | | Yes |
| Size | H x W x D (mm) | 207 x 75 x 34 |
| Max wire diameter | 30 mm (600 MCM) |
| Weight | 265 g |
| Category rating | | CAT III 600 V |
| | CAT IV 300 V |
| Warranty | | Two-year |
|